Customization: | Available |
---|---|
Function: | Flow Control |
Installation: | Threaded Cartridge |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CV5 Check Valve
OPERATION
Pressure at 1 overcomes the spring-bias poppet and allows free flow 1 to 2 . Flow in the oppdsite direction, from 2 to1 , is blocked by the poppet.
SPECIFICATIONS
Operating pressure:350Bar
Flow:See PRESSURE DROP VS. FLOW graph.
Internal leakage:5 drops/min. max. at 350 Bar
Crack pressure:
0.34=0.34Bar
1.7=1.7Bar
4.5=4.5Bar
6.9=6.9Bar
Temperature:-30 to + 120 degree C
Recommended Filtration:Critical Application - ISO 16/12
Non-Critical Application - ISO 19/15
Fluids:Mineral-based fluids.
CV5 function
CV5 dimension
CV5 flow